Book Contents

Book Index

Next Topic

Home

Restart Database With Catalog Version

Use this command only when instructed to do so by Technical Support.

This command discards changes made to the catalog back to a specific version. When a database starts up, all instances of Vertica must agree on a common catalog version. The dialog below appears when one or more nodes cannot agree on a catalog version, a situation that can occur when a cluster cannot shut down safely. The command allows you to discard versions of the catalog that did not get replicated on all nodes.

  1. On the Advanced menu select Roll Back Database To Catalog Version.

  2. Select the database to roll back. The database must be stopped.

  3. Click OK unless instructed to specify a catalog version number by Technical Support.

  4. Confirm that you really want to discard the catalog changes made after the specified version.

  5. The database restarts successfully.

    Database startup successful

    If the restart fails, you may have specified a catalog version that is not known to any node.